The most obvious is that rods naturally fall into water now, which dampens the neutron exchange to a stop, which works automatically in case of power cut (The rest of improvements are about preventing water from overheating and forming H2, and preventing H2 from overpressuring the chambers or exploding, which happened in both Chernobyl and Fukushima).